Is Your Navien Tankless Water Heater Reporting Errors?
Troubleshoot Your Issues Before Scheduling Service
Navien NPE Error Code E003
Ignition Failure
- Check if the manual gas valve is open
- Check the main gas supply
- For your safety and the health of your equipment, Call or Contact Hot Water Now! for further troubleshooting
- Verify that gas pressure is within operating range
- Check Dual Venturi for proper operation
- Check DIP Switch settings
- Check if the igniter is sparking
- Tighten the ground terminals on the heat exchanger
Navien NPE Error Code E004
Navien NPE Error Code E012
Flame Loss
- Check if the main gas valve is open
- Check the intake air filter
- Check the power supply
- For your safety and the health of your equipment, Call or Contact Hot Water Now! for further troubleshooting
- Verify the incoming gas pressure
- Check the ground wire
- Tighten the ground terminals on the heat exchanger
- Adjust the anti-short cycle time
Navien NPE Error Code E016
Heat exchanger overheat
- Turn OFF the unit, wait at least 30 min, and then restart
- Clean the inlet water filter and strainer
- Check the heat exchanger and flush it if required
- For your safety and the health of your equipment, Call or Contact Hot Water Now! for further troubleshooting
- Check the high limit switch and PCB
- Check pump operation (for A models only)
- Check the 3-way valve
- Check DIP Switch settings
Navien NPE Error Code E030
Exhaust Overheat: exhaust limit sensor shuts down the unit when the flue temperature exceeds 230 °F for more than 10 seconds.
- Turn OFF the unit, wait at least 30 min, and then restart
- Clean the inlet water filter and strainer
- Check the heat exchanger and flush it if required
- For your safety and the health of your equipment, Call or Contact Hot Water Now! for further troubleshooting
- Check exhaust thermistor and verify [K] value in DIAGNOSTIC mode
- Check DIP Switch settings
- Check the water adjustment valve
Navien NPE Error Code E047
Navien NPE Error Code E060
Navien NPE Error Code E109
Navien NPE Error Code E110
Exhaust blockage
- Check the intake/exhaust/condensate drain pipe for obstructions.(ice, snow, wildlife, etc)
- Check and clean the intake air filter
- For your safety and the health of your equipment, Call or Contact Hot Water Now! for further troubleshooting
- As a temporarily solution for troubleshooting purposes,restart the unit and/or remove the front cover
- Check if the igniter is sparking
- Tighten the ground terminals on the heat exchanger
Navien NPE Error Code E407
Navien NPE Error Code E421
Abnormal Cold water inlet thermistor open or short
- It's time to a or contact Hot Water Now!
- Check the thermistor
- Verify [C] value in DIAGNOSTIC mode
- Replace the thermistor
Navien NPE Error Code E432
Navien NPE Error Code E438
Abnormal circulation pump ("A" models only)
Navien NPE Error Code E439
Navien NPE Error Code E441
Navien NPE Error Code E445
Navien NPE Error Code E515
Abnormal PCB communication
- For your safety and the health of your equipment, Call or Contact Hot Water Now! for further troubleshooting
- Subcode 1~7 PCB > Ignitor: Check the PCB
- Subcode 8 PCB > Ignitor: Check PCB connection and ignitor
- Subcode 9 PCB > Fan: Check PCB connection and fan
- Subcode 10 Abnormal monitoring device of PCB: Check PCB connection and dual venturi
- Subcode 10~12 Abnormal communication between PCB and Dual Venturi: Check PCB connection and dual venturi
Navien NPE Error Code E517
Navien NPE Error Code E593
Navien NPE Error Code E594
Abnormal input data
- For your safety and the health of your equipment, Call or Contact Hot Water Now! for further troubleshooting
- Subcode 0 High limit switch of Heat exchanger: Check PCB
- Subcode 1 Exhaust sensor: check exhaust sensor connection and sensor
- Subcode 2 Flame rod: check flame rod connection and flame sensor
- Subcode 3~14 PCB: check the PCB
- Subcode 15 Below the range of input data from Pressure sensor: check pressure sensor wiring and output voltage of pressure sensor
- Subcode 16 Over the range of input data from Pressure sensor: check pressure sensor wiring and output voltage of pressure sensor
Navien NPE Error Code E736
Navien NPE Error Code E740
Abnormal outdoor temperature sensor open or short (appears only when the outdoor reset curve is enabled)
Navien NPE Error Code E760
Flushing / Service alarm
- A heat exchanger flush is required
Navien NPE Error Code E782
Abnormal main panel communication
- Check the PCB
Navien NPE Error Code E785
Abnormal flow sensor operation
- Check the Cold Water line
- Check the Flow Switch connection